@@ -15,6 +15,9 @@ use Moo::Role;
|
|
|
|
|
|
has 'binary' => ( is => 'ro', default => 'chromedriver' );
|
|
|
has 'binary_port' => ( is => 'ro', default => 9515 );
|
|
|
+ has '_binary_args' => ( is => 'ro', default => sub {
|
|
|
+ return ' --port=' . shift->port . ' --url-base=wd/hub ';
|
|
|
+ });
|
|
|
with 'Selenium::CanStartBinary';
|
|
|
1
|
|
|
};
|
|
|
@@ -77,6 +80,21 @@ until we find a valid one.
|
|
|
|
|
|
requires 'binary_port';
|
|
|
|
|
|
+=attr _binary_args
|
|
|
+
|
|
|
+Required: Specify the arguments that the particular binary needs in
|
|
|
+order to start up correctly. In particular, you may need to tell the
|
|
|
+binary about the proper port when we start it up, or that it should
|
|
|
+use a particular prefix to match up with the behavior of the Remote
|
|
|
+Driver server.
|
|
|
+
|
|
|
+If your binary doesn't need any arguments, just have the default be an
|
|
|
+empty string.
|
|
|
+
|
|
|
+=cut
|
|
|
+
|
|
|
+requires '_binary_args';
|
|
|
+
|
|
|
=attr port
|
|
|
|
|
|
The role will attempt to determine the proper port for us. Consuming
|
|
|
@@ -179,6 +197,10 @@ sub BUILDARGS {
|
|
|
# connect to localhost instead of 127.1
|
|
|
$args{remote_server_addr} = '127.0.0.1';
|
|
|
}
|
|
|
+ else {
|
|
|
+ $args{try_binary} = 0;
|
|
|
+ $args{binary_mode} = 0;
|
|
|
+ }
|
|
|
|
|
|
return { %args };
|
|
|
}
|
|
|
@@ -186,36 +208,40 @@ sub BUILDARGS {
|
|
|
sub _build_binary_mode {
|
|
|
my ($self) = @_;
|
|
|
|
|
|
- my $executable = $self->binary;
|
|
|
- return unless $executable;
|
|
|
+ # We don't know what to do without a binary driver to start up
|
|
|
+ return unless $self->binary;
|
|
|
|
|
|
+ # Either the user asked for 4444, or we couldn't find an open port
|
|
|
my $port = $self->port;
|
|
|
return unless $port != 4444;
|
|
|
+
|
|
|
if ($self->isa('Selenium::Firefox')) {
|
|
|
setup_firefox_binary_env($port);
|
|
|
}
|
|
|
- my $command = $self->_construct_command($executable, $port);
|
|
|
|
|
|
+ my $command = $self->_construct_command;
|
|
|
system($command);
|
|
|
+
|
|
|
my $success = wait_until { probe_port($port) } timeout => 10;
|
|
|
if ($success) {
|
|
|
return 1;
|
|
|
}
|
|
|
else {
|
|
|
- die 'Unable to connect to the ' . $executable . ' binary on port ' . $port;
|
|
|
+ die 'Unable to connect to the ' . $self->binary . ' binary on port ' . $port;
|
|
|
}
|
|
|
}
|
|
|
|
|
|
sub shutdown_binary {
|
|
|
my ($self) = @_;
|
|
|
|
|
|
- # TODO: Allow user to keep browser open after test
|
|
|
- $self->quit;
|
|
|
+ if ( $self->auto_close && defined $self->session_id ) {
|
|
|
+ $self->quit();
|
|
|
+ }
|
|
|
|
|
|
if ($self->has_binary_mode && $self->binary_mode) {
|
|
|
+ # Tell the binary itself to shutdown
|
|
|
my $port = $self->port;
|
|
|
my $ua = $self->ua;
|
|
|
-
|
|
|
$ua->get('127.0.0.1:' . $port . '/wd/hub/shutdown');
|
|
|
|
|
|
# Close the additional command windows on windows
|
|
|
@@ -240,6 +266,8 @@ sub shutdown_windows_binary {
|
|
|
system($kill);
|
|
|
}
|
|
|
|
|
|
+# We want to do things before the DEMOLISH phase, as during DEMOLISH
|
|
|
+# we apparently have no guarantee that anything is still around
|
|
|
before DEMOLISH => sub {
|
|
|
my ($self) = @_;
|
|
|
$self->shutdown_binary;
|
|
|
@@ -248,45 +276,31 @@ before DEMOLISH => sub {
|
|
|
sub DEMOLISH { };
|
|
|
|
|
|
sub _construct_command {
|
|
|
- my ($self, $executable, $port) = @_;
|
|
|
+ my ($self) = @_;
|
|
|
+ my $executable = $self->binary;
|
|
|
|
|
|
- # Handle spaces in executable path names
|
|
|
+ # Executable path names may have spaces
|
|
|
$executable = '"' . $executable . '"';
|
|
|
|
|
|
- my %args;
|
|
|
- if ($executable =~ /chromedriver(\.exe)?"$/i) {
|
|
|
- %args = (
|
|
|
- port => $port,
|
|
|
- 'url-base' => 'wd/hub'
|
|
|
- );
|
|
|
- }
|
|
|
- elsif ($executable =~ /phantomjs(\.exe)?"$/i) {
|
|
|
- %args = (
|
|
|
- webdriver => '127.0.0.1:' . $port
|
|
|
- );
|
|
|
- }
|
|
|
- elsif ($executable =~ /firefox(-bin|\.exe)"$/i) {
|
|
|
- $executable .= ' -no-remote ';
|
|
|
- }
|
|
|
-
|
|
|
- my @args = map { '--' . $_ . '=' . $args{$_} } keys %args;
|
|
|
+ # The different binaries take different arguments for proper setup
|
|
|
+ $executable .= $self->_binary_args;
|
|
|
|
|
|
# Handle Windows vs Unix discrepancies for invoking shell commands
|
|
|
my ($prefix, $suffix) = ($self->_cmd_prefix, $self->_cmd_suffix);
|
|
|
- return join(' ', ($prefix, $executable, @args, $suffix) );
|
|
|
+ return join(' ', ($prefix, $executable, $suffix) );
|
|
|
}
|
|
|
|
|
|
sub _cmd_prefix {
|
|
|
my ($self) = @_;
|
|
|
|
|
|
if (IS_WIN) {
|
|
|
- my $prefix = 'start "' . $self->window_title;
|
|
|
+ my $prefix = 'start "' . $self->window_title . '"';
|
|
|
|
|
|
# Let's minimize the command windows for the drivers that have
|
|
|
# separate binaries - but let's not minimize the Firefox
|
|
|
# window itself.
|
|
|
if (! $self->isa('Selenium::Firefox')) {
|
|
|
- $prefix .= '" /MIN ';
|
|
|
+ $prefix .= ' /MIN ';
|
|
|
}
|
|
|
return $prefix;
|
|
|
}
|